Our products

Product Group

Product Group
  • H2 Catalysts
  • H2 Measurement
  • Accessories

Product Area

Product Area
  • Gas purification
  • H2 combustion engines
  • H2 electrolyzers
  • H2 fuel cells
  • H2 process heat
  • Battery monitoring

Industry

Industry
  • Energy and Hydrogen economy
  • Industry & Production
  • Mobility & Transport
  • Research & Development
  • Air & Space

Sensor for battery monitoring

Sensor for H2 Purity measurement

Sensor for Automotive

O2 sensor for O2 measurement in electrolysis gas

Pressure, temperature and humidity Sensor

Sensor for H2 exhaust gas Measurement

High-temp. H2 sensor optionally Also with ATEX

Sensor for Industrial applications

NEO1002

Sensor for battery monitoring

H2 sensor system for Li-ion battery monitoring for automotive applications.

Lithium-ion cells can pose major hazards. Mechanical damage, water ingress, overcharging or deep discharging (see bottom page) can result in the build up of flammable gase. In worst-case scenario a fire or explosion can ocour.
The NEO1002 sensor system can monitor a battery/high-voltage storage system HVS and detects the hydrogen concentration, reducing and oxidizing gases, the gas pressure (pressure increase when gas escapes), water formation and also the battery temperature (“thermal runaway”) directly in the .

Most important features:

  • Measuring range: 0-2 vol.-% H2 (1⁄2 LEL)
  • Carrier gases Air
  • Measuring signal independent of ambient temperature and pressure
  • Detection of thermal runaway, pressure increase and reducing gases in a battery/rechargeable battery
  • Temperature measuring range: -40 to 85 °C
  • Pressure range: 0.6 – 2 bar absolute
  • Humidity: 0 – 90 % r.h. (non-condensing)
  • Response time: t90< 3 s
  • Recovery time: t10< 3 s
  • Signal: CAN 2.0 A/B with 125/250/500/1000 kbps

NEO1441

Sensor for H2 Purity measurement

Sensor system for measuring impurities in hydrogen gas with temperature and pressure-compensated signal evaluation for automotive applications. Applicable in the range: 0.6 – 5 bar a and -40°C – 85°C.

Most important features:

  • Measurements in the range of 0-10,000 ppmv Impurities in H2
  • Carrier gas hydrogen
  • Encrypted CAN communication on demand
  • Measuring signal independent of pressure, temperature and humidity
  • The gas concentration is not changed by the measurement.
  • Oxygen is not required for the measurement.
  • Signal output via CAN 2.0A
  • Connectors and contacts for crimping are included
  • Factory calibrated and ready for immediate use

NEO1XXX

Sensor for Automotive

The smart, simple version of our high-tech H2 concentration sensors are the sensors in the “neoOne” series (neo1XXX). They are significantly more cost-effective and smaller. Created from AEC-Q100 components, the sensor arrived from the factory pre-calibrated for immediate use.

Most important features:

  • Possible measuring ranges:
    • 0-5 vol.-% H2 NEO1005
    • 0-10 vol.-% H2 NEO1010
    • 0-100 vol.-% H2 NEO1100
  • Pressure range: 0.6 – 1.5 bara
  • Humidity: 0 – 100% r.h. (non-condensing)
  • Temperature measuring range: -40°C – 85°C (short-term up to 105°C).
  • Carrier gases: air, nitrogen, oxygen depleted air available
  • Measuring signal independent of pressure, temperature and humidity
  • Signal output via CAN 2.0 A/B with 125/250/500 kbps

The gas concentration is not changed by the measurement and oxygen is not required for operation.

NEO445

O2 sensor for O2 measurement in electrolysis gas

Oxygen concentration sensor for measuring the oxygen concentration in hydrogen with temperature-, pressure- and humidity-compensated signal evaluation for automotive or industrial applications

Important properties:

  • Temperature measuring range: 40°C – 120°C
  • Measuring ranges: 0-5 vol.-% O2
  • Carrier gas: Hydrogen
  • Measurement of electrolysis gases (O2 in H2)
  • Pressure range: 0.6 – 6 bar absolute
  • Humidity: 0 – 100% r.h. (non-condensing)
  • The gas concentration is not changed by the measurement.
  • Signal output via CAN 2.0, Modbus RTU via RS485, 0-10V or 4-20mA

NEO480

Pressure, temperature and humidity Sensor

Moisture-measuring triple sensor system with temperature and pressure-compensated signal evaluation. Typical applications are the detection of moisture in combustibles and in automobiles

Important properties:

  • Measuring range humidity dew point up to +90°C
  • Independent of pressure and temperature
  • Error control
  • Replacement for Vaisalla humidity sensors
  • Carrier gas: air, nitrogen, hydrogen
  • Pressure range: 0.6 – 6 bar absolute
  • Humidity: 0 – 100% r.h. (non-condensing)
  • The gas concentration is not changed by the measurement.
  • Signal output via CAN 2.0A / B or Modbus RTU/RS485

ATEX: Zone I available on request

NEO952

Sensor for H2 exhaust gas Measurement

Hydrogen sensor system for automotive applications for monitoring exhaust gases up to 5% H2 by volume at exhaust gas temperatures of up to 400°C.

Our hydrogen measurement system can quickly and accurately measure hydrogen in the exhaust gas of hydrogen internal combustion engines (ICE) / H2-fuelled petrol engines or solid oxide fuel cells (SOFC).
The measured values are output temperature-compensated via the CAN bus 2.0A/B with 125/250/500/1000 kbps.

Most important features:

  • Measurements to just above the lower explosion limit, i.e. 0 – 5 vol.-% H2
  • Tolerance:± 0.5 % by volume H2
  • Temperature measuring range: -40 to 400 °C
  • Pressure range: 0.6 to 1.5 bar absolute
  • Humidity: 0 to 100 % r.h. (non-condensing)
  • Response time: t90< 10 s
  • Recovery time: t10< 10 s
  • Signal: CAN 2.0A/B with 250/500 kbps

NEO9XXHT

High-temp. H2 sensor optionally Also with ATEX

The NEO974, NEO983 and NEO986 sensor systems are also available ATEX Zone I certification. These hightemperature sensorsare specified for use up to 120°C and are appropiate to use in both automotive and industrial applications.

Most important features:

  • Possible measuring ranges:
    • 0-5 vol.-% H2 NEO974HT-ATEX
    • 0-10 vol.-% H2 NEO983HT-ATEX
    • 0-100 vol.-% H2 NEO986HT-ATEX
  • II 2G/- Ex db IIB+H2 T1 Gb/- at -40°C< Ta< 100°C
  • Pressure range: 0.6 – 6 bara
  • Humidity: 0 – 100% r.h. (non-condensing)
  • Temperature measuring range: -40°C – 120°C.
  • Carrier gases: air, nitrogen, oxygen depleted air aviailable
  • Measuring signal independent of pressure, temperature and humidity
  • Signal output via CAN 2.0 A/B, Modbus RTU via RS485, 0-10V or 4-20mA
  • Replacement system for the AMS HLS-442, HLS-440P and the HPS-100

The gas concentration is not changed by the measurement and oxygen is not required for the measurement.

NEO9XXX

Sensor for Industrial applications

Sensor system for measuring the hydrogen concentration in air, oxygen, nitrogen or oxygen-depleted air with temperature-, pressure- and humidity-compensated signal evaluation for automotive or industrial applications. Applicable in the range: 0.6 – 5 bara, 0 – 100% r.h. (non-condensing) and 40°C – 120°C. A mathematical prediction algorithm ensures very fast response times.

Important properties:

  • Measuring ranges: 0-5 vol.-% H2 (NEO9005), 0-10 vol.-% H2 (NEO9010) or 0-100 vol.-% H2 (NEO9100)
  • Tolerance:± 0.3 vol.-% H2 or± 2 vol.-% H2
  • Pressure range: 0.6 – 6 bara
  • Humidity: 0 – 100% r.h. (non-condensing)
  • Temperature measuring range: -40°C – 120°C.
  • Carrier gases air, N2, O2, oxygen-depleted air, methane, synthetic natural gas are possible
  • Measuring signal independent of pressure, temperature and humidity
  • Signal output via CAN 2.0, Modbus RTU via RS485, 0-10V or 4-20mA
  • Oxygen is not required for the measurement. No sample extraction necessary.
  • Can also be used in the intake manifold for H2 direct injection

Suitable for concentration measurement in the ventilation of the crankcase or in the recirculation of the fuel cell (recirculation sensor; for controlling the purge valve)